GMI: glucose management indicator calculator
The GMI (glucose management indicator) converts the mean glucose from continuous glucose monitoring (CGM) into a value expressed as a percentage, comparable with HbA1c. It replaces the former estimated HbA1c for CGM data.
Multiply the mean glucose (mg/dL) by 0.02392 and add 3.31.
Enter the mean glucose from continuous monitoring to calculate the GMI.
Check the value: mean glucose 40 to 400 mg/dL.
GMI %
Glucose management indicator
Percentage value that indicates the approximate HbA1c expected with that mean glucose. It may differ from laboratory-measured HbA1c; both values are interpreted together.
| Result | Interpretation |
|---|---|
| GMI in % | Estimate of HbA1c from CGM |
Reference tool for health professionals. The GMI does not replace laboratory HbA1c or clinical judgment. Data are processed only in your browser; they are not sent, not stored and not added to any medical record.
Formula
GMI (%) = 3.31 + 0.02392 × mean glucose (mg/dL)
The formula was derived from the relationship between mean glucose from CGM sensors and laboratory HbA1c in recent clinical trials.
Interpretation
The GMI indicates the approximate HbA1c that would correspond to the recorded mean glucose. Bergenstal and colleagues proposed the name GMI to avoid confusing it with measured HbA1c, from which it may differ in the same patient.
Limitations
The GMI depends on the quantity and quality of the sensor data; calculate it with several weeks of data. Measured HbA1c may differ from the GMI because of anemia, hemoglobinopathies, changes in red cell lifespan or individual differences in glycation.
Frequently asked questions
Why does my GMI not match my HbA1c?
HbA1c also depends on red cell lifespan and each person's glycation, and it reflects a different period from the one recorded by the sensor. That is why the GMI and HbA1c can differ.
Sources
- Formula and Interpretation: Bergenstal RM, Beck RW, Close KL, et al. Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring. Diabetes Care. 2018;41(11):2275-2280. https://doi.org/10.2337/dc18-1581